Description
|
Reason(s)
|
Troubleshooting
|
Solution
|
Dead in Water
|
Defective Power Supply, Cable or Pump
|
1) Check voltage from Power Supply (~ 30 Vdc)
2) Check continuity/voltage through cable (~30 Vdc)
3) Check for water entry to Pump
4) Check voltage to Pump Motor (~30 Vdc)
|
The problem lies where the power dies.
|
Unit not moving
|
0 Vdc to Drive Motor or Defective Drive Motor
|
1) Check voltage to Drive Motor (~18-20 Vdc)
|
If the voltage to the Drive Motor is ~18Vdc then the motor is defective and should be replaced. If the voltage to the Drive Motor is 0Vdc then the Pump Motor should be replaced.
|
No Suction
|
Defective Cable or Defective Pump Motor
|
1) Check voltage from Power Supply (~ 30 Vdc)
2) Check voltage through cable (~30 Vdc)
3) Check voltage to Pump Motor (~30 Vdc)
|
The problem lies where the power dies.
|
Unit Standing/Making Frequent Turns
|
Defective Pump Motor or Defective Sensor Wheels
|
1) Check for water entry to Pump Motor
2) Check continuity through Sensor Wheels
|
If there is continuity to through the Sensor Wheels then there is an issue in the programming and the Pump Motor should be replaced. If there is a defect found with the sensor wheels then the Chassis has to be replaced.
|
Description
|
Reason(s)
|
Troubleshooting
|
Solution
|
Unit Spinning (NC71)
|
One side of Drive Motor is Defective
|
1) Rotate motor by hand to feel resistance
2) Test Drive Motor independently
|
If there is a large amount of resistance in one side of motor; then the motor is defective.
|
Unit Floating
|
Old Style Filter Bag or Fault in Vertical Sensor
|
1) Check Filter Bag and replace with new if necessary-test
2) Check sensor in pump motor
|
If the cleaner has an old style filter bag and the vertical sensor is ok; then test the cleaner with a new style filter bag.
|
Unit Not Climbing
|
Worn Brushes/Ring, Defective Cable, Drive or Pump Motor
|
1) Check for wear on brushes/ring
2) Check voltage from Power Supply (~ 30 Vdc)
3) Check continuity/voltage through cable (~30 Vdc)
4) Check for water entry to Pump
5) Check voltage to Pump Motor (~30 Vdc)
6) Check voltage to Drive Motor (~18-20 Vdc)
7) Check continuity of sensor wheels
|
Change all worn parts if necessary. Check the vertical sensor and any sign of water entry to the pump motor. The problem lies where the power dies.
|